LIGHT MICROSCOPY / PRODUCTS / FLUORESCENCE


Filter Combinations for Epi-Fluorescence

Recommendation by Carl Zeiss


Fluorochrome: [ A-C ] [ D-G ] [ H-P ] [ Q-Z ]

Fluorochrome Spectral
Data
Filter sets
Exitat. Emiss. recommended
filter
combination
combination
suitable to a
limit extent
filter set for
synchronous
double/tripple
fluorescence
Acridin yellow 470 550 9,10    
Acridin orange + DNA 502 526 9,10 16,17  
Acridin orange + RNA 460 650 9    
Acriflavin-Feulgen 480 550-
600
9,16    
Adrenaline     5    
Alizarin complexon 530-
560
580 14,15    
Allophycocyanin 630 660   0  
AMCA 345 425 2 1  
7-Amino-
actinomycin D
555 655 0,14,15    
Amino-
methylcumarine
354 441 1,2    
6-Amino-
Quinolin
360 443 1,2    
Atebrin 436 490 6    
Auramin 460 550 9,10    
Auraphospinmin 460 550 7    
BAO (Ruch) 280 460 1,2    
BCECF 430/
480
520 on requestx)
Berberine sulfate 430 550 6,7,9    
BOBO-1 462 481 5,6    
BOBO-3 570 602 14,15    
BODIPY 503 512 9,10    
BODIPY 581/591
phalloidin
584 592 14,15    
Calcein 495 500-
550
  9,10  
Calcein blue 375 420-
450
  2  
Calcium Crimson 588 611 14,15    
Calcium Green 554 575 9,10,14,15    
Calcium Orange 506 531 14,15    
Calcofluorwhite 440 500-
520
5 6,7  
Cascade blue 376/
399
423 2    
Catecholamine 410 470 5    
Chinacrin 450-
490
515 6    
Chlorotetracycline     5,9    
Chromomycin/
mitramycin
436-
460
470 5,7    
Coriphosphin 460 575 9    
CPM 385 471 1,2    
CTC 5-cyano-2,3-ditolyl-
Tetrazolium-Chlorid
602   5 7,18  
Cyanine Cy2 489 505 9    
Cyanine Cy3 575 605 15,20    
Cyanine Cy5 640 705 26    

legend:
x) combination on request (partly compiled from non-standard filters).


All filter combinations are mentioned for Axio-line microscopes.

We like to inform you about the new double and tripple bandpass filter sets. At the same time we present a new list of fluorochromes for our filter combinations. Please take this as an invitation to communicate about important missing fluorochromes or fluorochromes that nobody uses any longer. Please remind that shown maxima of excitation and emmision don´t fit to every application and therefore the indicated filter set must´nt be at optimum. If the operator uses another salt of the compound or the pH-value is different than excitation and emission could be changed completely.
In such cases we will help you: [email protected].

Filter sets:

              Filter set 0                    Filter set 1                 Filter set 2                 Filter set 5
              Filter set 6                    Filter set 9                 Filter set 10               Filter set 14
              Filter set 15                  Filter set 16               Filter set 17               Filter set 18
              Filter set 21/30             Filter set 23               Filter set 24               Filter set 25
              Filter set 26                  Filter set 27               Filter set 28